MilkoScope Farmer
Automatic
 
 
MilkoScope Expert
Automatic
 
 
MilkoScope
Partner Automatic
 
 
MilkoScope
Partner
Doublo Automatic
 
 
Julie C2 Automatic
 
 
Julie C3 Automatic
 
 
Julie C5 Automatic
 
 
Julie C8 Automatic
 
 
Julie Z7 Automatic
 
 
 
 
 
 
MilkoScope Farmer Automatic
ZOOM

Case : INOX
LED display
The most portable milk analyzer of Scope Electric

It can be adjusted to function at 24V, working and powered in a truck.

The milk analyzer has 3 calibration channels for three types of milk – they are to be chosen by the client. One of the calibrations is included in the analyzer’s price – the other/s should be paid.

Cleaning – automatic, with the MilkoScope – Flush cleaning concentrate.

MilkoScope Farmer is suitable for small farms and milk-collecting centers. If the client has chosen the 24V function, with the Farmer can be equipped all the trucks of the milk-processing company. This feature gives the possibility for quality control at the milk collection spot.


Measuring Ranges:
Ňĺchnical Overview:
 Fat:
0% - 12%
 Sample Volume:
5-12 ml.
 Protein:
0% - 7%
 Sample Speed:
70 sec.
 Lactose:
0% - 7%
 Sample Temperature:
5 - 30°C
 Solids-Non-Fat (SNF):
0% - 15%
 Humidity:
0 - 80% RH
 Density:
1000-1200 kg/m3
 Database Processing:
RS 232 port
 Added Water:
0% - 100%
 Power Supply:
110/230VAC±10%,50/60Hz
 Sample Temperature:
5 - 30°C
 Power Consumption:
25W
 
 Dimension:
H=225 mm,W=130 mm,D=240 mm
 
 Weight:
2,4 kg

Accuracy:
Ęit:
 Fat:
±0.05%
against Rose Gottlieb
 Ěilk Analyzer
 Protein:
±0.05%
against Kjeldahl
 Power Supply Cable 220V
 Lactose:
±0.05%
against Polarimetry
 Serial Cable to PC
1piece
 Solids-Non-Fat:
±0.01%
against Drying Oven
 Sample Cup
1piece
 Density:
±0,3 kg/m3
against pycnometer
 Spare Hose
1piece
 Added Water:
±3%
against cryoscope
 Cleaning Concentrate
1piece
 
 User’s Manual
     CD with software
Deviation at numerous analyses of one and
the same sample: ±0.05% for all parameters.

MilkoScope Expert Automatic
<<<
ZOOM

Case – INOX
Scope - pipette for automatic start of the measurement
LCD display, 4 rows, 16 symbols

Built-in device for coping with distortions, caused by electricity malfunctions.

PC connection option with a cable and software, included in the analyzer’s kit. Thermal printer connection option – to be chosen by the client.

The milk analyzer has 3 calibration channels, which can be set for 3 types of milk – to be chosen by the client.

One calibration is included in the analyzer’s price – the other/s should be paid.

Cleaning – automatic with the MilkoScope – Flush cleaning concentrate.

Written and sound message for necessity of cleaning.

Expert Automatic is Scope Electric’s best sold model, which has long ago proven its qualities.

Suitable for measurement of all types of animal milk.


Measuring Ranges:
Ňĺchnical Overview:
 Fat:
0% - 12%
 Sample Volume:
5-12 ml.
 Protein:
0% - 7%
 Sample Speed:
65 sec.
 Lactose:
0% - 7%
 Sample Temperature:
5 - 30°C
 Solids-Non-Fat (SNF):
0% - 15%
 Humidity:
0 - 80% RH
 Solids:
0% - 5%
 Database Processing:
RS 232 port
 Density:
1000-1200 kg/m3
 Power Supply:
110/230VAC±10%,50/60Hz
 Added Water:
0% - 100%
 Power Consumption:
30W
 Freezing Point:
-0,400 tî -0,700°C
 Dimension:
H=270 mm,W=130 mm,D=280 mm
 Sample Temperature:
5 - 30°C
 Weight:
3 kg

Accuracy:
Ęit:
 Fat:
±0.03%
against Rose Gottlieb
 Ěilk Analyzer
 Protein:
±0.03%
against Kjeldahl
 Power Supply Cable 220V
 Lactose:
±0.03%
against Polarimetry
 Serial Cable to PC
1piece
 Solids-Non-Fat (SNF):
±0.05%
against Drying Oven
 Sample Cup
1piece
 Solids:
±0.03%
against Gravimetric
 Waste Container
1piece
 Density:
±0,3 kg/m3
against pycnometer
 Spare Hose
1piece
 Added Water:
±2%
against cryoscope
 Cleaning Concentrate
1piece
 Freezing Point:
0,005 °C
 User’s Manual
   
 CD with software
Deviation at numerous analyses of one and
the same sample: ±0.02% for all parameters.

MilkoScope Partner Automatic
<<<
ZOOM

One of Scope Electric’s latest models. New-generation measuring sensor. Innovative decisions, which make it the perfect milk analyzer we invented for you.

Case – INOX
LCD display, 4 rows, 16 symbols
Scope – system for automatic start of the analysis

Built-in device for coping with distortions, caused by electricity malfunctions.

PC connection option with a cable and software, included in the analyzer’s kit.

Thermal printer connection option – to be chosen by the client.

The milk analyzer has 3 calibration channels, which can be set for 3 types of milk – to be chosen by the client.

One calibration is included in the analyzer’s price – the other/s should be paid.

Cleaning – manual and automatic, with the MilkoScope – Flush cleaning concentrate.

Written and sound message for necessity of cleaning.

Suitable for analysis of all types of animal milk.


Measuring Ranges:
Ňĺchnical Overview:
 Fat:
0% - 15%
 Sample Volume:
5-12 ml.
 Protein:
0% - 8%
 Sample Speed:
65 sec.
 Lactose:
0% - 7%
 Sample Temperature:
5 - 30°C
 Solids-Non-Fat (SNF):
0% - 15%
 Humidity:
0 - 80% RH
 Solids:
0% - 5%
 Database Processing:
RS 232 port
 Density:
1000-1200 kg/m3
 Power Supply:
110/230VAC±10%,50/60Hz
 Added Water:
0% - 100%
 Power Consumption:
30W
 Freezing Point:
-0,400 tî -0,700°C
 Dimension:
H=270 mm,W=170 mm,D=280 mm
 Sample Temperature:
5 - 30°C
 Weight:
3,1 kg

Accuracy:
Ęit:
 Fat:
±0.04%
against Rose Gottlieb
 Ěilk Analyzer
 Protein:
±0.03%
against Kjeldahl
 Power Supply Cable 220V
 Lactose:
±0.03%
against Polarimetry
 Serial Cable to PC
1piece
 Solids-Non-Fat (SNF):
±0.05%
against Drying Oven
 Sample Cup
1piece
 Solids:
±0.03%
against Gravimetric
 Waste Container
1piece
 Density:
±0,3 kg/m3
against pycnometer
 Spare Hose
1piece
 Added Water:
±2%
against cryoscope
 Cleaning Concentrate
1piece
 Freezing Point:
0,005 °C
 User’s Manual
   
 CD with software
Deviation at numerous analyses of one and
the same sample: ±0.02% for all parameters.

MilkoScope Partner Doublo Automatic
<<<
ZOOM

If you have a lot of samples for analysis and you can not succeed in measuring all of them with Partner Automatic, your best decision for this situation is Partner Doublo Automatic.

Two independent systems and two measuring modules are gathered in one case. They will help you shorten the analysis time, without affecting the results’ accuracy. Partner Doublo Automatic was developed at the base of our clients’ countless requests, wanting the measurement of more samples for one hour.

Case – INOX
LCD display, 4 rows, 16 symbols
Scope – system for automatic start of the analysis

Built-in device coping with distortions, caused by electricity malfunctions.

PC connection option with a cable and software, included in the analyzer’s kit.

Thermal printer connection option – to be chosen by the client.

The milk analyzer has 6 calibration channels, which can be set for 6 types of milk, chosen by the client.

Two calibrations are included in the analyzer’s price – the other/s should be paid.

Cleaning – manual and automatic, with the MilkoScope – Flush cleaning concentrate.

Written and sound message for necessity of cleaning.

Suitable for analysis of all types of animal milk.


Measuring Ranges:
Ňĺchnical Overview:
 Fat:
0% - 15%
 Sample Volume:
5-12 ml.
 Protein:
0% - 8%
 Sample Speed:
65 sec.
 Lactose:
0% - 7%
 Sample Temperature:
5 - 30°C
 Solids-Non-Fat (SNF):
0% - 15%
 Humidity:
0 - 80% RH
 Solids:
0% - 5%
 Database Processing:
RS 232 port
 Density:
1000-1200 kg/m3
 Power Supply:
110/230VAC±10%,50/60Hz
 Added Water:
0% - 100%
 Power Consumption:
30W
 Freezing Point:
-0,400 tî -0,700°C
 Dimension:
H=270 mm,W=330 mm,D=280 mm
 Sample Temperature:
5 - 30°C
 Weight:
5,3 kg

Accuracy:
Ęit:
 Fat:
±0.04%
against Rose Gottlieb
 Ěilk Analyzer
 Protein:
±0.03%
against Kjeldahl
 Power Supply Cable 220V
 Lactose:
±0.03%
against Polarimetry
 Serial Cable to PC
2piece
 Solids-Non-Fat (SNF):
±0.05%
against Drying Oven
 Sample Cup
2piece
 Solids:
±0.03%
against Gravimetric
 Waste Container
2piece
 Density:
±0,3 kg/m3
against pycnometer
 Spare Hose
2piece
 Added Water:
±2%
against cryoscope
 Cleaning Concentrate
2piece
 Freezing Point:
0,005 °C
 User’s Manual
   
 CD with software
Deviation at numerous analyses of one and
the same sample: ±0.02% for all parameters.

Julie C2 Automatic
<<<